The XPS Core is centered around a state-of-the-art Kratos AXIS Supra+ X-ray Photoelectron Spectroscopy (XPS) platform equipped with multiple complementary surface analysis techniques designed to provide comprehensive chemical and electronic characterization of complex material systems.
To submit a request, visit the XPS Core iLab page. To get started with iLab, visit our Resource and Training Toolbox.
XPS/UPS/ISS/REELS/AES Waitlist
Our Pricing and Procedures
XPS pricing was developed for University of South Carolina users, for non-USC academic investigators and for industrial users. Please download the appropriate spreadsheet, compile the cost estimate calculator, and return with the Sample Information Sheet.
| User Type | XPS Usage with Assistance | XPS Usage without Assistance | Cat Cell Usage* | Staff Time** |
|---|---|---|---|---|
| Internal | $110/hr | $55/hr | $35/sample | $55/hr |
| External Academia | $164/hr | $82/hr | $52/sample | $82/hr |
| Industry | $275/hr | $137/hr | $88/sample | $137/hr |
*Catalysis Cell/Gas Cell/Reaction Cell user fee is per sample
**Staff time for Instrument Operation, Data Analysis & Gas Cell Operations
Kratos Axis Supra+ XPS Instrument Details:
- Monochromatic Al Kα and Ag Lα X-ray sources
- High-resolution XPS chemical imaging and mapping
- Angle-Resolved XPS (ARXPS)
- Field Emission Gun for:
- Auger Electron Spectroscopy (AES),
- Scanning Auger Microscopy (SAM) and
- Reflection Electron Energy Loss Spectroscopy (REELS)
- Ultraviolet Photoelectron Spectroscopy (UPS)
- Ion Scattering Spectroscopy (ISS)
- Ion Gun for Sputter Cleaning and Depth Profile Analysis
- Monoatomic Ar+ ion sputtering
- Argon gas cluster sizes up to Ar3000+ are available
- In-situ catalysis and reaction cell
- Temperatures upto 1000 0C
- Pressure upto 30bar
- Available gases H2, O2, N2, Ar, He, CO2, special gasses upon request
Data Acquisition and Processing Policy
The XPS Research Core provides users with flexible options for data handling, processing, and publication credit. Please review the following policy carefully before initiating work at the facility.
Option 1 – User-Processed Data
Users receive raw data and perform their own processing.
Option 2 – Facility-Processed Data
The facility provides both data acquisition and data processing services.
Option 3 – Co-Authorship Model
Users are charged only for the data acquisition time; core staff process the data.
Acknowledgement Template
Users must include the following acknowledgment/s in any publication that uses data from the XPS Core, per the models above:
Option 1 & 2
X-ray Photoelectron Spectroscopy (XPS) data were collected at the XPS Research Core
(RRID: SCR_026176), financially supported by the Office of the Vice President for
Research, University of South Carolina. We thank the XPS facility staff Dr. S. K.
Balijepalli for assistance with data collection.
Options 3
X-ray Photoelectron Spectroscopy (XPS) data were collected at the XPS Research Core
(RRID: SCR_026176), financially supported by the Office of the Vice President for
Research, University of South Carolina.
Author Affiliation:
Santosh Kiran Balijepalli or S. K. Balijepalli
Office of the Vice President for Research, University of South Carolina, Columbia,
SC, United States, 29201.
Connect on iLab
Visit the X-Ray Photoelectron Spectroscopy (XPS) on iLab for more information about services and equipment.